Service of Custom Design and Fab of PDMS Chips by 3D Printed Molds

Service of Custom Design and Fab of PDMS Chips by 3D Printed Molds

NBT Original

  • €96,00
    Unit price per 
Shipping calculated at checkout.


WHEN YOU NEED A SPECIFIC TYPE OF CHIP FOR YOUR RESEARCH NEEDS WE PROVIDE CUSTOM DESIGN AND FABRICATION SOLUTION. PDMS MILLIFLUIDICS/MICROFLUIDICS CHIPS MADE BY 3D PRINTED MOLDS ARE CHEAPER SOLUTIONS AND PROVIDE HIGHER THICKNESS FOR TISSUE CULTURING MICROBIOREACTORS.

ALL PRICES ARE WITHOUT VAT AND THE SHIPPING COSTS CAN BE SEEN AT THE SHOPPING CART AFTER PROVIDING SHIPPING ADDRESS.

ABOUT YOUR CHIP DESIGN AND IF DIFFERENT NUMBER OF CHIP PIECES IS NEEDED, PLEASE CONTACT US.

 

Microfludics is the future and we are ready to serve for your ideas in

--- Life Sciences
--- Parmaceutical Sciences
--- Biotechnology
--- Diagnostic tech
--- or Others

Specification Info
Material PDMS bonded on microscopy glass or other materials using chips holders. Please also check "Our Trip to PDMS Chips" blog post.
Bonding technique Oxygen plasma treatment to bond PDMS chips on microscope glass. Holders can also be used for PDMS on various materials.
XY Size of total chip The max size of chip can be 50x50 mm or 50 in diameter. (due to 3D Printer stage size)
Z Height of PDMS chip The thickness of PDMS can be min 1.0 mm and max 5.0 mm, suggested
XY Size of microchannels The microchannel size can be min 250 microns and max 30.0 mm, suggested
Z Height of microchannels The height of microchannels can be min 250 microns and 10 mm, suggested
Aspect ratio and Resolution Resolution of 50 microns at Aspect Ratio of 5:1 which means 250 micron XY microstructures can be formed with 50 microns of Z microchannel height minimum.
Fabrication method 3D Printed Mold fabricated by DLP/SLA Printer technique using photosensitive resin.
Ports on top/edge

on Top, suggested

on Edge, possible

... ...

 

Additional Requirements Suggestions
Pumping/Actuation Flow and mixing of the liquids inside microchannels require low-pulsation flow.
Some high-quality syringe pumps and pressure pumps work well.
Peristaltic and piezoelectronic pumps may also be suitable but mind the possible relatively high pulsation.
Fittings All fittings in ufluidic.com are suitable with this chip. Any other connectors compatible with pitch and port size is also applicable. Reactive compability of the fittings is also important to be considered.
Chemicals Depends on the application of researcher.
Visualisation Epi-Fluorescent Microscopy is widely used together with microfluidic chips.
Other analysis techniques should be determined by user researchers for the experiments where optical changes inside chips do not occur.
... ...

 


 Kullanım Kılavuzu
 ... 
 Nasıl Kullanılır - Multimedya  ...
   


We Also Recommend